Get Started DES-1241 Exam [2022] Dumps EMC PDF Questions [Q44-Q69]

Share

Get Started: DES-1241 Exam [2021] Dumps EMC PDF Questions

DES-1241 Premium Exam Engine pdf Download


Understanding functional and technical aspects of DES-1241 Specialist – Platform Engineer, PowerStore Exam PowerStore Implementation

The following will be discussed in DELL DES-1241 exam dumps:

  • Initial configuration steps
  • Ethernet switching configuration process
  • PowerStore networks
  • PowerStore licensing
  • Ethernet switching, network requirements, configuration options

Understanding functional and technical aspects of DES-1241 Specialist – Platform Engineer, PowerStore Exam PowerStore Maintenance

The following will be discussed in DELL DES-1241 exam dumps:

  • Replacement procedures
  • Power control for maintenance procedures
  • PowerStore CRUs and FRUs
  • ESD handling procedures

 

NEW QUESTION 44
Which component is a CRU?

  • A. Base enclosure
  • B. Battery Backup Unit
  • C. Expansion enclosure
  • D. Nodes

Answer: D

Explanation:
https://www.dellemc.com/content/dam/digitalassets/active/en/unauth/manual-warranty-informations/h4276-emc-prod-warranty-maint-table.pdf

 

NEW QUESTION 45
Which component is a CRU?

  • A. Nodes
  • B. Battery Backup Unit
  • C. Base enclosure
  • D. Expansion enclosure

Answer: C

 

NEW QUESTION 46
What is the default log collection schedule?

  • A. As scheduled during install
  • B. Weekly
  • C. Daily
  • D. Hourly

Answer: A

 

NEW QUESTION 47
What are the recommended number of network switches in a Dell EMC PowerStore T environment?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-ntwk-plang/ powerstore-t-model-appliance-networks?guid=guid-97a3e988-c1bc-4f51-a445-3af23f19da1b&lang=en-us

 

NEW QUESTION 48
When planning for a Dell EMC PowerStore T implementation, how many IP addresses are required for the storage network?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

 

NEW QUESTION 49
Which port is used to SSH from one Dell EMC PowerStore appliance to another?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

Explanation:
Explanation/Reference: https://topics-cdn.dell.com/pdf/pwrstr-scg_en-us.pdf

 

NEW QUESTION 50
What describes the ICM and ICD networks?

  • A. Address type is persistent throughout the life of the cluster and CANNOT to be modified
  • B. Address type is dynamic and automatically reconfigured on discovery results
  • C. They are encrypted with IPsec
  • D. They are NOT encrypted

Answer: C

 

NEW QUESTION 51
While on-site installing a Dell EMC PowerStore T system, the node A embedded module management Ethernet port link LED is off. What does this indicate?

  • A. Port speed is 10 GB/s
  • B. Network connection is established
  • C. Port speed is 1 GB/s
  • D. No network connection is established

Answer: D

Explanation:
Explanation/Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-isg/embedded- module-leds?guid=guid-bc07892c-75cf-43b6-8f17-8a4c49001aeb&lang=en-us

 

NEW QUESTION 52
During Dell EMC PowerStore startup, both appliance nodes have rebooted in service mode. What must be done first to avoid management software conflicts?

  • A. Return node A to normal mode
  • B. Disable node B boot mode
  • C. Clear the boot mode
  • D. Reboot node B

Answer: A

Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-1000/pwrstr-isg/power-control- procedure-considerations?guid=guid-4352c94e-0ae7-4a2e-8593-9ae135bb9e34&lang=en-us

 

NEW QUESTION 53
Which Dell EMC PowerStore model reserves the last two slots of the base enclosure for NVMe NVRAM?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

Explanation:
Reference:
https://www.dellemc.com/en-us/collaterals/unauth/white-papers/products/storage/h18241-dell-emc- powerstore-best-practices-guide.pdf (9)

 

NEW QUESTION 54
Order the steps to prepare for an NDU process.

Answer:

Explanation:

 

NEW QUESTION 55
Refer to the exhibit.

What is the result of the network configuration show for a Dell EMC PowerStore T node A management port?

  • A. VLAN 1 passes tagged traffic, VLAN 1501 passes untagged traffic
  • B. VLAN 1 and VLAN 1501 pass untagged traffic
  • C. VLAN 1 passes untagged traffic, VLAN 1501 passes tagged traffic
  • D. VLAN 1 and VLAN 1501 pass tagged traffic

Answer: B

 

NEW QUESTION 56
What describes the power requirements for Dell EMC PowerStore?

  • A. T models require less total power than X models
  • B. Lower model numbered systems require less input voltage (VAC) than higher model numbered systems
  • C. X models require less total power than T models
  • D. Lower model numbered systems require less AC line current than higher model numbered systems

Answer: D

Explanation:
Maximum input power 240 VAC ± 10%, single phase For 100-120V, a customer-supplied step-up transformer is required AC Line Current (operating maximum at 200 VAC) 8.1 A 8.1 A 9.0 A 9.0 A 9.3 A 10.4 A https://www.dell.com/support/manuals/en-us/powerstore-5000/pwrstr-plang/power-requirements-for-powerstore-x-model-and-powerstore-t-model?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us

 

NEW QUESTION 57
When connecting a PowerStore base enclosure to 2 expansion enclosures, match the base SAS ports in column A to their corresponding expansion LCC ports in column B.

Answer:

Explanation:

Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-1000/pwrstr-isg/cable-the-base-enclosure-to- the-expansion-enclosure?guid=guid-d68d049f-2b77-489f-b1ab-553f4f3de8aa&lang=en-us

 

NEW QUESTION 58
Through which network do external hosts connect to the cluster for data access?

  • A. Storage
  • B. Management
  • C. ICD
  • D. ICM

Answer: A

Explanation:
Reference:
https://topics-cdn.dell.com/pdf/pwrstr-hcg_en-us.pdf

 

NEW QUESTION 59
During Dell EMC PowerStore startup, both appliance nodes have rebooted in service mode. What must be done first to avoid management software conflicts?

  • A. Return node A to normal mode
  • B. Disable node B boot mode
  • C. Clear the boot mode
  • D. Reboot node B

Answer: A

 

NEW QUESTION 60
Refer to the exhibit.

A Storage Administrator is troubleshooting a Dell EMC PowerStore T hardware issue. They observe that the base enclosure LED circled is blue. What does this indicate?

  • A. Cluster has only a single appliance
  • B. Base enclosure has a component hardware fault
  • C. Base enclosure hardware is operating normally
  • D. Appliance has a node in service mode

Answer: C

 

NEW QUESTION 61
Refer to the exhibit.

A Storage Administrator noticed a drive LED blinking blue. What does this indicate?

  • A. Identification is on
  • B. Access activity
  • C. Is faulted
  • D. Power up

Answer: D

 

NEW QUESTION 62
Refer to the exhibit.

A Storage Administrator noticed a solid amber LED. What does this mean?

  • A. Drive rebuilding
  • B. Power up
  • C. Drive identification on
  • D. Drive faulted

Answer: D

Explanation:
Explanation/Reference: https://www.dell.com/support/article/en-pk/sln321266/powerstore-understanding-led-colors-and- states-for-troubleshooting?lang=en

 

NEW QUESTION 63
Refer to the exhibit.

Which column indicates the master appliance?

  • A. Service Tag
  • B. IP Address
  • C. Model
  • D. Mode

Answer: B

 

NEW QUESTION 64
A Storage Administrator has just installed PSTCLI on a Linux client. The administrator is unfamiliar with the PSTCLI command list. How can the administrator get a list of all PSTCLI commands from the cli> prompt?

  • A. Type the <Ctrl>+keys together
  • B. Use the help all command
  • C. Press the <Tab> key
  • D. Use the show all command

Answer: B

Explanation:
https://dl.dell.com/topicspdf/pwrstr-cliug_en-us.pdf

 

NEW QUESTION 65
Refer to the exhibit.

What is indicated when the circled LED on the node embedded module is illuminated solid amber?

  • A. Node is faulted
  • B. System is booting
  • C. Cluster is uninitialized
  • D. Module is faulted

Answer: D

 

NEW QUESTION 66
A Storage Administrator needs to connect through SSH to run svc commands. How is the SSH session configured?

  • A. NAS server IP address using port 26
  • B. NAS server IP address using port 22
  • C. Appliance IP address using port 22
  • D. Appliance IP address using port 26

Answer: B

 

NEW QUESTION 67
What describes the power requirements for Dell EMC PowerStore?

  • A. T models require less total power than X models
  • B. Lower model numbered systems require less input voltage (VAC) than higher model numbered systems
  • C. X models require less total power than T models
  • D. Lower model numbered systems require less AC line current than higher model numbered systems

Answer: D

Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore/pwrstr-plang/power- requirements?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us

 

NEW QUESTION 68
When looking at the base enclosure front view, what does a solid amber drive LED indicate?

  • A. Faulted drive
  • B. Normal activity
  • C. Discover new drive
  • D. Rebuild activity

Answer: A

 