NEW QUESTION 44
Which component is a CRU?
- A. Base enclosure
- B. Battery Backup Unit
- C. Expansion enclosure
- D. Nodes
Answer: D
Explanation:
https://www.dellemc.com/content/dam/digitalassets/active/en/unauth/manual-warranty-informations/h4276-emc-prod-warranty-maint-table.pdf
NEW QUESTION 45
Which component is a CRU?
- A. Nodes
- B. Battery Backup Unit
- C. Base enclosure
- D. Expansion enclosure
Answer: C
NEW QUESTION 46
What is the default log collection schedule?
- A. As scheduled during install
- B. Weekly
- C. Daily
- D. Hourly
Answer: A
NEW QUESTION 47
What are the recommended number of network switches in a Dell EMC PowerStore T environment?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-ntwk-plang/ powerstore-t-model-appliance-networks?guid=guid-97a3e988-c1bc-4f51-a445-3af23f19da1b&lang=en-us
NEW QUESTION 48
When planning for a Dell EMC PowerStore T implementation, how many IP addresses are required for the storage network?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
NEW QUESTION 49
Which port is used to SSH from one Dell EMC PowerStore appliance to another?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
Explanation:
Explanation/Reference: https://topics-cdn.dell.com/pdf/pwrstr-scg_en-us.pdf
NEW QUESTION 50
What describes the ICM and ICD networks?
- A. Address type is persistent throughout the life of the cluster and CANNOT to be modified
- B. Address type is dynamic and automatically reconfigured on discovery results
- C. They are encrypted with IPsec
- D. They are NOT encrypted
Answer: C
NEW QUESTION 51
While on-site installing a Dell EMC PowerStore T system, the node A embedded module management Ethernet port link LED is off. What does this indicate?
- A. Port speed is 10 GB/s
- B. Network connection is established
- C. Port speed is 1 GB/s
- D. No network connection is established
Answer: D
Explanation:
Explanation/Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-isg/embedded- module-leds?guid=guid-bc07892c-75cf-43b6-8f17-8a4c49001aeb&lang=en-us
NEW QUESTION 52
During Dell EMC PowerStore startup, both appliance nodes have rebooted in service mode. What must be done first to avoid management software conflicts?
- A. Return node A to normal mode
- B. Disable node B boot mode
- C. Clear the boot mode
- D. Reboot node B
Answer: A
Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-1000/pwrstr-isg/power-control- procedure-considerations?guid=guid-4352c94e-0ae7-4a2e-8593-9ae135bb9e34&lang=en-us
NEW QUESTION 53
Which Dell EMC PowerStore model reserves the last two slots of the base enclosure for NVMe NVRAM?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
Explanation:
Reference:
https://www.dellemc.com/en-us/collaterals/unauth/white-papers/products/storage/h18241-dell-emc- powerstore-best-practices-guide.pdf (9)
NEW QUESTION 54
Order the steps to prepare for an NDU process.
Answer:
Explanation:
NEW QUESTION 55
Refer to the exhibit.
What is the result of the network configuration show for a Dell EMC PowerStore T node A management port?
- A. VLAN 1 passes tagged traffic, VLAN 1501 passes untagged traffic
- B. VLAN 1 and VLAN 1501 pass untagged traffic
- C. VLAN 1 passes untagged traffic, VLAN 1501 passes tagged traffic
- D. VLAN 1 and VLAN 1501 pass tagged traffic
Answer: B
NEW QUESTION 56
What describes the power requirements for Dell EMC PowerStore?
- A. T models require less total power than X models
- B. Lower model numbered systems require less input voltage (VAC) than higher model numbered systems
- C. X models require less total power than T models
- D. Lower model numbered systems require less AC line current than higher model numbered systems
Answer: D
Explanation:
Maximum input power 240 VAC ± 10%, single phase For 100-120V, a customer-supplied step-up transformer is required AC Line Current (operating maximum at 200 VAC) 8.1 A 8.1 A 9.0 A 9.0 A 9.3 A 10.4 A https://www.dell.com/support/manuals/en-us/powerstore-5000/pwrstr-plang/power-requirements-for-powerstore-x-model-and-powerstore-t-model?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us
NEW QUESTION 57
When connecting a PowerStore base enclosure to 2 expansion enclosures, match the base SAS ports in column A to their corresponding expansion LCC ports in column B.
Answer:
Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-1000/pwrstr-isg/cable-the-base-enclosure-to- the-expansion-enclosure?guid=guid-d68d049f-2b77-489f-b1ab-553f4f3de8aa&lang=en-us
NEW QUESTION 58
Through which network do external hosts connect to the cluster for data access?
- A. Storage
- B. Management
- C. ICD
- D. ICM
Answer: A
Explanation:
Reference:
https://topics-cdn.dell.com/pdf/pwrstr-hcg_en-us.pdf
NEW QUESTION 59
During Dell EMC PowerStore startup, both appliance nodes have rebooted in service mode. What must be done first to avoid management software conflicts?
- A. Return node A to normal mode
- B. Disable node B boot mode
- C. Clear the boot mode
- D. Reboot node B
Answer: A
NEW QUESTION 60
Refer to the exhibit.
A Storage Administrator is troubleshooting a Dell EMC PowerStore T hardware issue. They observe that the base enclosure LED circled is blue. What does this indicate?
- A. Cluster has only a single appliance
- B. Base enclosure has a component hardware fault
- C. Base enclosure hardware is operating normally
- D. Appliance has a node in service mode
Answer: C
NEW QUESTION 61
Refer to the exhibit.
A Storage Administrator noticed a drive LED blinking blue. What does this indicate?
- A. Identification is on
- B. Access activity
- C. Is faulted
- D. Power up
Answer: D
NEW QUESTION 62
Refer to the exhibit.
A Storage Administrator noticed a solid amber LED. What does this mean?
- A. Drive rebuilding
- B. Power up
- C. Drive identification on
- D. Drive faulted
Answer: D
Explanation:
Explanation/Reference: https://www.dell.com/support/article/en-pk/sln321266/powerstore-understanding-led-colors-and- states-for-troubleshooting?lang=en
NEW QUESTION 63
Refer to the exhibit.
Which column indicates the master appliance?
- A. Service Tag
- B. IP Address
- C. Model
- D. Mode
Answer: B
NEW QUESTION 64
A Storage Administrator has just installed PSTCLI on a Linux client. The administrator is unfamiliar with the PSTCLI command list. How can the administrator get a list of all PSTCLI commands from the cli> prompt?
- A. Type the <Ctrl>+keys together
- B. Use the help all command
- C. Press the <Tab> key
- D. Use the show all command
Answer: B
Explanation:
https://dl.dell.com/topicspdf/pwrstr-cliug_en-us.pdf
NEW QUESTION 65
Refer to the exhibit.
What is indicated when the circled LED on the node embedded module is illuminated solid amber?
- A. Node is faulted
- B. System is booting
- C. Cluster is uninitialized
- D. Module is faulted
Answer: D
NEW QUESTION 66
A Storage Administrator needs to connect through SSH to run svc commands. How is the SSH session configured?
- A. NAS server IP address using port 26
- B. NAS server IP address using port 22
- C. Appliance IP address using port 22
- D. Appliance IP address using port 26
Answer: B
NEW QUESTION 67
What describes the power requirements for Dell EMC PowerStore?
- A. T models require less total power than X models
- B. Lower model numbered systems require less input voltage (VAC) than higher model numbered systems
- C. X models require less total power than T models
- D. Lower model numbered systems require less AC line current than higher model numbered systems
Answer: D
Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore/pwrstr-plang/power- requirements?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us
NEW QUESTION 68
When looking at the base enclosure front view, what does a solid amber drive LED indicate?
- A. Faulted drive
- B. Normal activity
- C. Discover new drive
- D. Rebuild activity
Answer: A
NEW QUESTION 69
......