
Huawei H31-341-ENU Exam Questions (Updated 2022) 100% Real Question Answers
Pass Huawei H31-341-ENU Exam Quickly With TestPDF
Prerequisites of Huawei H31-341 Exam
Before you go ahead and take up the Huawei H31-341 exam, it is essential that you keep in mind the prerequisites of this exam. It will make things much easier for you when it comes to your preparations for this exam. So here are some of the prerequisites:
- The minimum qualification required in order to attend the Huawei H31-341 exam is graduation.
- There is no age limit to take up this exam.
- You need to have 4 years of experience in this field.
- You need to pass a Huawei H31-341 test in order to get certified by Huawei.
What are the benefits of Huawei H31-341 certified professional
- This certification will also help you to get an interview with top IT companies.
- The Huawei HiLTE certification will help you to get a distinct career in IT.
- Take this exam and become certified in the Huawei HiLTE.
- Our exam product will help you to understand the questions that may come up in the actual Huawei HiLTE exam.
- You will be given an opportunity to work with top IT companies.
- Take this exam at least six months prior to the actual Huawei HiLTE exam.
NEW QUESTION 75
Which of the following are limitations of the alarm and performance analysis methods? (Multiple Choice)
- A. When some faults occur, there may be no obvious alarms or performance events reported, and sometimes no alarms or performance events are found.
- B. The network administrator cannot obtain the current notifications of the device, the alarm occurrence time, and the historical alarm of the device.
- C. Field maintenance personnel cannot understand the current operating condition of the equipment.
- D. In the case of complex networking, service, and fault information, many alarms and performance events may occur along with the occurrence of faults. Due to too many reports and performance events, maintenance personnel are unable to analyze.
Answer: A,D
NEW QUESTION 76
The OD system monitors the main optical path performance in each optical multiplexing section (OMS),which of the following items are monitored?
- A. whether the optical power of the transmit-end OA board is out of the permitted range.
- B. whether the line loss exceeds the design end of life (EOL) value
- C. whether the line loss compensation is out of the permitted range.
- D. whether a fiber cut occurs on the main optical path.
Answer: D
NEW QUESTION 77
Which of the following statements about Flexible ROADM is incorrect?
- A. The WSMD2 board supports the Flexible ROADM configuration.
- B. Flexible ROADM is compatible with existing networks.
- C. The Flexible grid technology can flexibly set bandwidth and support flexible bandwidth allocation and scheduling.
- D. Improves spectrum utilization and meets the requirements for flexible scheduling in the 100 Gbit/s era.
Answer: C
NEW QUESTION 78
Which of the following statement is correct?
- A. The optical layer path must be deleted first when the electrical layer path is removed.
- B. When the OCh path exists, you can directly create a client path. The NMS automatically creates an ODUk path.
- C. Deactivation will delete the configuration of the U2000, which has no impact on the device side services.
- D. The optical layer path and the electrical layer path are independent. It is not necessary to delete the electrical layer path when deleting the optical layer path.
Answer: D
NEW QUESTION 79
Which layer of the TCP/IP protocol is the TCP/UDP protocol located?
- A. Data link layer
- B. Application layer
- C. Network layer
- D. Transport layer
Answer: D
NEW QUESTION 80
What are the ways that NG WDM devices create fibers? (Multiple Choice)
- A. Synchronization method
- B. Graphic method
- C. Search method
- D. Form method
Answer: B,C,D
NEW QUESTION 81
The E-Line service types supported by the MS-OTN packet device are: (Multiple Choice)
- A. E-Line carried by PW
- B. E-Line service based on QinQ
- C. E-Line service based on VL.AN
- D. Point-to-point transparent transmission of E-Line services
Answer: A,B,C,D
NEW QUESTION 82
When the grooming service level of the line board is ODUflex, which of the following protection schemes can be supported?
- A. SW SNCP
- B. Tributary SNCP
- C. ODUk SPRing protection
- D. ODUk SNCP
Answer: A
NEW QUESTION 83
Which of the following is the client-side logical port of a board in standard mode?
- A. RX/TX-n
- B. ClientLP-n
- C. ODUkLP-n
- D. n(Nn/OUTn)-OCH:l-ODUk:m-ODUp:q
Answer: C
NEW QUESTION 84
When performing fiber synchronization, the network element does not create a fiber. What does it indicate?
- A. Fiber connection that does not exist on the network management side and the NE side.
- B. The fiber connection exists on both the network management side and the network element side.
- C. Fiber connection exists only on the local network management side.
- D. Fiber connection only on the NE side.
Answer: C
NEW QUESTION 85
The setting of alarm reversal is based on:
- A. Veneer
- B. Port
- C. Network element
- D. Alarm
Answer: B
NEW QUESTION 86
NS4 as 100G line service processing board. In the following description of the NS4 board, which is wrong?
- A. Support 80-way ODU0/ODUflex or 40-way ODU1 or 10-way ODU2/ODU2e or 2-way ODU3 or 1-way ODU4 signal and cross-board to realize service cross-scheduling.
- B. It can be used in electrical relay stations to realize the electrical relay function of the corresponding optical signals.
- C. The wavelength of the wavelength division side optical signal is adjustable within 80 waves of the C-band 50 GHz interval.
- D. The MS4 board does not support the intersection of ODUI services with the ND2 board through the centralized crossover bus.
Answer: B
NEW QUESTION 87
In the non-aggregated OTU processing SDH standard signal scenario, both A and B are WDM stations, and the R_Los alarm is detected on the client side of the OTU of the A station. After the alarm is processed on the WDM side of the OTU, the client side of the downstream B station detects and reports the REM_SF alarm, and the B station transmits the signal to the downstream client device and reports the R_LOS alarm to the client device.
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION 88
The maximum optical power of light-emitting OBU output is 20dBm, which is used in the C-band 80 system. How much dBm should the single-wave standard output optical power be?
- A. +4dBm
- B. +1dBm
- C. +7dBm
- D. -2dBm
Answer: B
NEW QUESTION 89
In the WDM system, after a certain distance of transmission, the optical signal-to-noise ratio of the receiving signal will be reduced to a certain extent. What is the main reason?
- A. Use of EDFA
- B. Fiber attenuation is too large
- C. Use of the splitter combiner
- D. No new fiber is used
Answer: A
NEW QUESTION 90
The reasons for the discrete business are? (Multiple choice)
- A. The logical fiber connection of the network element is inconsistent with the physical fiber connection.
- B. There is an outbound subnet service whose source or sink port is not within the scope of network management.
- C. The network element side configuration data is not uploaded to the U2000.
- D. The cross-connection configuration on the network element is wrong.
Answer: A,B,C,D
NEW QUESTION 91
When different routes are used for client-side 1 + 1 protection, the working wavelength and protection wavelength cannot use the same wavelength.
- A. False
- B. True
Answer: A
NEW QUESTION 92
In WDM systems, when using less than () wavelength, it is ideal to use a dielectric thin film filter (TFF).
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION 93
......
Get to know about the Need for Huawei H31-341 Exam
The Huawei H31-341 exam is one of the essential elements for acquiring any type of IT certification. This exam helps you to validate your skills and knowledge about Huawei HiLTE. Learning key IT concepts would also help you to understand how technology can be used in day-to-day life. The more you study technology-related subjects, the more value you will add to your resume. H31-341 Dumps has been created by an industry expert who has years of experience in this field. Exam products of our company are the only products that will help you to understand the topics and design questions. It has been categorized based on class and difficulty level. We have made sure that you will not once face a problem while taking this exam. All our customers are given a free updates for 3 months. Exam materials of our company are highly compatible with the real exam. We have more than 10,000 customers in more than 50 countries of the world.
Account and password of our company are given to each and every customer. Our exam is compiled of 100% authentic test questions from the real Huawei H31-341 exam. As a result, you will get a clear idea about the topics and design questions of the actual exam. Register an account in our company and download your product. You can easily download your Huawei H31-341 exam from the account. In case of any problem, you can also contact our customer care executives. Regular basis updates are given to our customers so that they can be updated with the new questions and answers. We have a team of industry experts who give you the best experience. All our products are made in a way that they can be used along with your daily routine. With the help of these products, you will get an amazing result and also have a good chance to work with top companies. You can get your certification today and start a new journey in a new career. So, these are some of the basic things that you need to know about our product before taking up the Huawei H31-341 certification exam.
Real Huawei H31-341-ENU Exam Questions [Updated 2022]: https://www.testpdf.com/H31-341-ENU-exam-braindumps.html
